What are these cloth covered wires?

The name of the pictureThe name of the pictureThe name of the pictureClash Royale CLAN TAG#URR8PPP





.everyoneloves__top-leaderboard:empty,.everyoneloves__mid-leaderboard:empty margin-bottom:0;







up vote
2
down vote

favorite












Continuing to install some new light fixtures and I pulled these wires out of an old switch box. There are 3 wires sheathed in a cloth-like material. The three wires are then wrapped altogether in another cloth-like-material, and finally that is all in a ribbed metal conduit. I looked around online but couldn't definitively figure out what these are.



enter image description hereenter image description here



Are these safe to use? What time period are these from?










share|improve this question







New contributor




bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.



















  • Not a full answer, but these are old wires that shouldn't be used anymore. They aren't up to any kind of modern building code. If they are still being used, consider having the house rewired, more for house and family safety than any building code reasoning.
    – computercarguy
    3 hours ago







  • 3




    @computercarguy Old wiring is not inherently unsafe. Particularly, cloth covered wiring properly installed and inside grounded metal conduit should be fine unless damaged somehow. AFCI breakers can help a lot to alleviate concerns about decaying insulation and other problems. But essentially cloth covered wiring is what they used before plastic.
    – manassehkatz
    3 hours ago










  • @manassehkatz, granted the links I'm going to provide are from businesses that deal in replacing wiring, but the safety concerns are valid for cloth wiring. kilowatthvac.com/blog/electrical/worried-about-cloth-wiring theelectricconnection.com/cloth-insulated-wiring kingelectricservice.com/cable.html
    – computercarguy
    3 hours ago
















up vote
2
down vote

favorite












Continuing to install some new light fixtures and I pulled these wires out of an old switch box. There are 3 wires sheathed in a cloth-like material. The three wires are then wrapped altogether in another cloth-like-material, and finally that is all in a ribbed metal conduit. I looked around online but couldn't definitively figure out what these are.



enter image description hereenter image description here



Are these safe to use? What time period are these from?










share|improve this question







New contributor




bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.



















  • Not a full answer, but these are old wires that shouldn't be used anymore. They aren't up to any kind of modern building code. If they are still being used, consider having the house rewired, more for house and family safety than any building code reasoning.
    – computercarguy
    3 hours ago







  • 3




    @computercarguy Old wiring is not inherently unsafe. Particularly, cloth covered wiring properly installed and inside grounded metal conduit should be fine unless damaged somehow. AFCI breakers can help a lot to alleviate concerns about decaying insulation and other problems. But essentially cloth covered wiring is what they used before plastic.
    – manassehkatz
    3 hours ago










  • @manassehkatz, granted the links I'm going to provide are from businesses that deal in replacing wiring, but the safety concerns are valid for cloth wiring. kilowatthvac.com/blog/electrical/worried-about-cloth-wiring theelectricconnection.com/cloth-insulated-wiring kingelectricservice.com/cable.html
    – computercarguy
    3 hours ago












up vote
2
down vote

favorite









up vote
2
down vote

favorite











Continuing to install some new light fixtures and I pulled these wires out of an old switch box. There are 3 wires sheathed in a cloth-like material. The three wires are then wrapped altogether in another cloth-like-material, and finally that is all in a ribbed metal conduit. I looked around online but couldn't definitively figure out what these are.



enter image description hereenter image description here



Are these safe to use? What time period are these from?










share|improve this question







New contributor




bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.











Continuing to install some new light fixtures and I pulled these wires out of an old switch box. There are 3 wires sheathed in a cloth-like material. The three wires are then wrapped altogether in another cloth-like-material, and finally that is all in a ribbed metal conduit. I looked around online but couldn't definitively figure out what these are.



enter image description hereenter image description here



Are these safe to use? What time period are these from?







electrical wiring






share|improve this question







New contributor




bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.











share|improve this question







New contributor




bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.









share|improve this question




share|improve this question






New contributor




bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.









asked 4 hours ago









bfink

234




234




New contributor




bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.





New contributor





bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.






bfink is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.











  • Not a full answer, but these are old wires that shouldn't be used anymore. They aren't up to any kind of modern building code. If they are still being used, consider having the house rewired, more for house and family safety than any building code reasoning.
    – computercarguy
    3 hours ago







  • 3




    @computercarguy Old wiring is not inherently unsafe. Particularly, cloth covered wiring properly installed and inside grounded metal conduit should be fine unless damaged somehow. AFCI breakers can help a lot to alleviate concerns about decaying insulation and other problems. But essentially cloth covered wiring is what they used before plastic.
    – manassehkatz
    3 hours ago










  • @manassehkatz, granted the links I'm going to provide are from businesses that deal in replacing wiring, but the safety concerns are valid for cloth wiring. kilowatthvac.com/blog/electrical/worried-about-cloth-wiring theelectricconnection.com/cloth-insulated-wiring kingelectricservice.com/cable.html
    – computercarguy
    3 hours ago
















  • Not a full answer, but these are old wires that shouldn't be used anymore. They aren't up to any kind of modern building code. If they are still being used, consider having the house rewired, more for house and family safety than any building code reasoning.
    – computercarguy
    3 hours ago







  • 3




    @computercarguy Old wiring is not inherently unsafe. Particularly, cloth covered wiring properly installed and inside grounded metal conduit should be fine unless damaged somehow. AFCI breakers can help a lot to alleviate concerns about decaying insulation and other problems. But essentially cloth covered wiring is what they used before plastic.
    – manassehkatz
    3 hours ago










  • @manassehkatz, granted the links I'm going to provide are from businesses that deal in replacing wiring, but the safety concerns are valid for cloth wiring. kilowatthvac.com/blog/electrical/worried-about-cloth-wiring theelectricconnection.com/cloth-insulated-wiring kingelectricservice.com/cable.html
    – computercarguy
    3 hours ago















Not a full answer, but these are old wires that shouldn't be used anymore. They aren't up to any kind of modern building code. If they are still being used, consider having the house rewired, more for house and family safety than any building code reasoning.
– computercarguy
3 hours ago





Not a full answer, but these are old wires that shouldn't be used anymore. They aren't up to any kind of modern building code. If they are still being used, consider having the house rewired, more for house and family safety than any building code reasoning.
– computercarguy
3 hours ago





3




3




@computercarguy Old wiring is not inherently unsafe. Particularly, cloth covered wiring properly installed and inside grounded metal conduit should be fine unless damaged somehow. AFCI breakers can help a lot to alleviate concerns about decaying insulation and other problems. But essentially cloth covered wiring is what they used before plastic.
– manassehkatz
3 hours ago




@computercarguy Old wiring is not inherently unsafe. Particularly, cloth covered wiring properly installed and inside grounded metal conduit should be fine unless damaged somehow. AFCI breakers can help a lot to alleviate concerns about decaying insulation and other problems. But essentially cloth covered wiring is what they used before plastic.
– manassehkatz
3 hours ago












@manassehkatz, granted the links I'm going to provide are from businesses that deal in replacing wiring, but the safety concerns are valid for cloth wiring. kilowatthvac.com/blog/electrical/worried-about-cloth-wiring theelectricconnection.com/cloth-insulated-wiring kingelectricservice.com/cable.html
– computercarguy
3 hours ago




@manassehkatz, granted the links I'm going to provide are from businesses that deal in replacing wiring, but the safety concerns are valid for cloth wiring. kilowatthvac.com/blog/electrical/worried-about-cloth-wiring theelectricconnection.com/cloth-insulated-wiring kingelectricservice.com/cable.html
– computercarguy
3 hours ago










2 Answers
2






active

oldest

votes

















up vote
2
down vote













That is Armored Cable, or commonly called BX which is a brand. Its from before the widespread use of modern polyethylene and synthetic plastics for insulation on wires. The copper wires in the BX cable are coated in rubber and wrapped in cloth. The issue over time is the rubber becomes dried out, brittle and crumbly. Once its moved around or bent then it can easily break open. Its fine as installed but you should be careful as you work with it. Its easy to crack and then sort if anything comes in contact with the copper wire When bending the wires into a new box you may notice a crack and should wrap that in electrical tape. Your picture is a 3 conductor cable, probably used on a fixture that had a 3-way switch. Black hot, White Neutral, Red is traveler.



The metal sheathing of BX cable is the grounding conductor, and this type of cable should be clamped to a metal box. Then your fixture grounding is connect to that metal box or the housing is metal and screwed to the box. It looks like in your picture this isn't a box installed anymore, and there is a Romex cable in the mix. If you intent to keep the BX cable, you'll need to connect the grounds together somehow, such as install a metal box, clamp the metal sheathing into the box, and connect the bare copper ground from the Romex and copper ground wire from your fixture to a pigtail anchored to the metal box.






share|improve this answer



























    up vote
    2
    down vote













    In answer to your question the wires you are looking at are part of a cabling system known a BX. It is a lot like AC or MC only it doesn't have a grounding conductor and the conductor insulation is a type RH or RHW which is a rubber insulation wrapped in cloth. The other cloth is just fill.



    This type of wiring was used in the late 1940's, 1950's and early 1960's until a more modern plastic insulation type offered better protection. Bx was known to be the cause of some fires during its use and was outlawed in many municipalities. One because as you can see there was no anti-short bushing (sometimes referred to as red devils and other names), which cut the insulation and started a high resistance short. Also when exposed to harsh (outdoor) environments or high heat at a junction it would dry out and crack exposing the bare conductor. Also as I have mentioned before there was no acceptable ground connection.



    I wouldn't go so far as to say this type of system is alright, but the key is the insulation if it is still malleable and covers the conductor well it should be OK. If it shows any sign of drying out and cracking it should be replaced, and if you are reconnecting it back up use the anti-short bushings to protect the wire.



    Stay safe.






    share|improve this answer




















      Your Answer







      StackExchange.ready(function()
      var channelOptions =
      tags: "".split(" "),
      id: "73"
      ;
      initTagRenderer("".split(" "), "".split(" "), channelOptions);

      StackExchange.using("externalEditor", function()
      // Have to fire editor after snippets, if snippets enabled
      if (StackExchange.settings.snippets.snippetsEnabled)
      StackExchange.using("snippets", function()
      createEditor();
      );

      else
      createEditor();

      );

      function createEditor()
      StackExchange.prepareEditor(
      heartbeatType: 'answer',
      convertImagesToLinks: false,
      noModals: false,
      showLowRepImageUploadWarning: true,
      reputationToPostImages: null,
      bindNavPrevention: true,
      postfix: "",
      noCode: true, onDemand: true,
      discardSelector: ".discard-answer"
      ,immediatelyShowMarkdownHelp:true
      );



      );






      bfink is a new contributor. Be nice, and check out our Code of Conduct.









       

      draft saved


      draft discarded


















      StackExchange.ready(
      function ()
      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f148582%2fwhat-are-these-cloth-covered-wires%23new-answer', 'question_page');

      );

      Post as a guest






























      2 Answers
      2






      active

      oldest

      votes








      2 Answers
      2






      active

      oldest

      votes









      active

      oldest

      votes






      active

      oldest

      votes








      up vote
      2
      down vote













      That is Armored Cable, or commonly called BX which is a brand. Its from before the widespread use of modern polyethylene and synthetic plastics for insulation on wires. The copper wires in the BX cable are coated in rubber and wrapped in cloth. The issue over time is the rubber becomes dried out, brittle and crumbly. Once its moved around or bent then it can easily break open. Its fine as installed but you should be careful as you work with it. Its easy to crack and then sort if anything comes in contact with the copper wire When bending the wires into a new box you may notice a crack and should wrap that in electrical tape. Your picture is a 3 conductor cable, probably used on a fixture that had a 3-way switch. Black hot, White Neutral, Red is traveler.



      The metal sheathing of BX cable is the grounding conductor, and this type of cable should be clamped to a metal box. Then your fixture grounding is connect to that metal box or the housing is metal and screwed to the box. It looks like in your picture this isn't a box installed anymore, and there is a Romex cable in the mix. If you intent to keep the BX cable, you'll need to connect the grounds together somehow, such as install a metal box, clamp the metal sheathing into the box, and connect the bare copper ground from the Romex and copper ground wire from your fixture to a pigtail anchored to the metal box.






      share|improve this answer
























        up vote
        2
        down vote













        That is Armored Cable, or commonly called BX which is a brand. Its from before the widespread use of modern polyethylene and synthetic plastics for insulation on wires. The copper wires in the BX cable are coated in rubber and wrapped in cloth. The issue over time is the rubber becomes dried out, brittle and crumbly. Once its moved around or bent then it can easily break open. Its fine as installed but you should be careful as you work with it. Its easy to crack and then sort if anything comes in contact with the copper wire When bending the wires into a new box you may notice a crack and should wrap that in electrical tape. Your picture is a 3 conductor cable, probably used on a fixture that had a 3-way switch. Black hot, White Neutral, Red is traveler.



        The metal sheathing of BX cable is the grounding conductor, and this type of cable should be clamped to a metal box. Then your fixture grounding is connect to that metal box or the housing is metal and screwed to the box. It looks like in your picture this isn't a box installed anymore, and there is a Romex cable in the mix. If you intent to keep the BX cable, you'll need to connect the grounds together somehow, such as install a metal box, clamp the metal sheathing into the box, and connect the bare copper ground from the Romex and copper ground wire from your fixture to a pigtail anchored to the metal box.






        share|improve this answer






















          up vote
          2
          down vote










          up vote
          2
          down vote









          That is Armored Cable, or commonly called BX which is a brand. Its from before the widespread use of modern polyethylene and synthetic plastics for insulation on wires. The copper wires in the BX cable are coated in rubber and wrapped in cloth. The issue over time is the rubber becomes dried out, brittle and crumbly. Once its moved around or bent then it can easily break open. Its fine as installed but you should be careful as you work with it. Its easy to crack and then sort if anything comes in contact with the copper wire When bending the wires into a new box you may notice a crack and should wrap that in electrical tape. Your picture is a 3 conductor cable, probably used on a fixture that had a 3-way switch. Black hot, White Neutral, Red is traveler.



          The metal sheathing of BX cable is the grounding conductor, and this type of cable should be clamped to a metal box. Then your fixture grounding is connect to that metal box or the housing is metal and screwed to the box. It looks like in your picture this isn't a box installed anymore, and there is a Romex cable in the mix. If you intent to keep the BX cable, you'll need to connect the grounds together somehow, such as install a metal box, clamp the metal sheathing into the box, and connect the bare copper ground from the Romex and copper ground wire from your fixture to a pigtail anchored to the metal box.






          share|improve this answer












          That is Armored Cable, or commonly called BX which is a brand. Its from before the widespread use of modern polyethylene and synthetic plastics for insulation on wires. The copper wires in the BX cable are coated in rubber and wrapped in cloth. The issue over time is the rubber becomes dried out, brittle and crumbly. Once its moved around or bent then it can easily break open. Its fine as installed but you should be careful as you work with it. Its easy to crack and then sort if anything comes in contact with the copper wire When bending the wires into a new box you may notice a crack and should wrap that in electrical tape. Your picture is a 3 conductor cable, probably used on a fixture that had a 3-way switch. Black hot, White Neutral, Red is traveler.



          The metal sheathing of BX cable is the grounding conductor, and this type of cable should be clamped to a metal box. Then your fixture grounding is connect to that metal box or the housing is metal and screwed to the box. It looks like in your picture this isn't a box installed anymore, and there is a Romex cable in the mix. If you intent to keep the BX cable, you'll need to connect the grounds together somehow, such as install a metal box, clamp the metal sheathing into the box, and connect the bare copper ground from the Romex and copper ground wire from your fixture to a pigtail anchored to the metal box.







          share|improve this answer












          share|improve this answer



          share|improve this answer










          answered 3 hours ago









          freshop

          94118




          94118






















              up vote
              2
              down vote













              In answer to your question the wires you are looking at are part of a cabling system known a BX. It is a lot like AC or MC only it doesn't have a grounding conductor and the conductor insulation is a type RH or RHW which is a rubber insulation wrapped in cloth. The other cloth is just fill.



              This type of wiring was used in the late 1940's, 1950's and early 1960's until a more modern plastic insulation type offered better protection. Bx was known to be the cause of some fires during its use and was outlawed in many municipalities. One because as you can see there was no anti-short bushing (sometimes referred to as red devils and other names), which cut the insulation and started a high resistance short. Also when exposed to harsh (outdoor) environments or high heat at a junction it would dry out and crack exposing the bare conductor. Also as I have mentioned before there was no acceptable ground connection.



              I wouldn't go so far as to say this type of system is alright, but the key is the insulation if it is still malleable and covers the conductor well it should be OK. If it shows any sign of drying out and cracking it should be replaced, and if you are reconnecting it back up use the anti-short bushings to protect the wire.



              Stay safe.






              share|improve this answer
























                up vote
                2
                down vote













                In answer to your question the wires you are looking at are part of a cabling system known a BX. It is a lot like AC or MC only it doesn't have a grounding conductor and the conductor insulation is a type RH or RHW which is a rubber insulation wrapped in cloth. The other cloth is just fill.



                This type of wiring was used in the late 1940's, 1950's and early 1960's until a more modern plastic insulation type offered better protection. Bx was known to be the cause of some fires during its use and was outlawed in many municipalities. One because as you can see there was no anti-short bushing (sometimes referred to as red devils and other names), which cut the insulation and started a high resistance short. Also when exposed to harsh (outdoor) environments or high heat at a junction it would dry out and crack exposing the bare conductor. Also as I have mentioned before there was no acceptable ground connection.



                I wouldn't go so far as to say this type of system is alright, but the key is the insulation if it is still malleable and covers the conductor well it should be OK. If it shows any sign of drying out and cracking it should be replaced, and if you are reconnecting it back up use the anti-short bushings to protect the wire.



                Stay safe.






                share|improve this answer






















                  up vote
                  2
                  down vote










                  up vote
                  2
                  down vote









                  In answer to your question the wires you are looking at are part of a cabling system known a BX. It is a lot like AC or MC only it doesn't have a grounding conductor and the conductor insulation is a type RH or RHW which is a rubber insulation wrapped in cloth. The other cloth is just fill.



                  This type of wiring was used in the late 1940's, 1950's and early 1960's until a more modern plastic insulation type offered better protection. Bx was known to be the cause of some fires during its use and was outlawed in many municipalities. One because as you can see there was no anti-short bushing (sometimes referred to as red devils and other names), which cut the insulation and started a high resistance short. Also when exposed to harsh (outdoor) environments or high heat at a junction it would dry out and crack exposing the bare conductor. Also as I have mentioned before there was no acceptable ground connection.



                  I wouldn't go so far as to say this type of system is alright, but the key is the insulation if it is still malleable and covers the conductor well it should be OK. If it shows any sign of drying out and cracking it should be replaced, and if you are reconnecting it back up use the anti-short bushings to protect the wire.



                  Stay safe.






                  share|improve this answer












                  In answer to your question the wires you are looking at are part of a cabling system known a BX. It is a lot like AC or MC only it doesn't have a grounding conductor and the conductor insulation is a type RH or RHW which is a rubber insulation wrapped in cloth. The other cloth is just fill.



                  This type of wiring was used in the late 1940's, 1950's and early 1960's until a more modern plastic insulation type offered better protection. Bx was known to be the cause of some fires during its use and was outlawed in many municipalities. One because as you can see there was no anti-short bushing (sometimes referred to as red devils and other names), which cut the insulation and started a high resistance short. Also when exposed to harsh (outdoor) environments or high heat at a junction it would dry out and crack exposing the bare conductor. Also as I have mentioned before there was no acceptable ground connection.



                  I wouldn't go so far as to say this type of system is alright, but the key is the insulation if it is still malleable and covers the conductor well it should be OK. If it shows any sign of drying out and cracking it should be replaced, and if you are reconnecting it back up use the anti-short bushings to protect the wire.



                  Stay safe.







                  share|improve this answer












                  share|improve this answer



                  share|improve this answer










                  answered 3 hours ago









                  Retired Master Electrician

                  7,525420




                  7,525420




















                      bfink is a new contributor. Be nice, and check out our Code of Conduct.









                       

                      draft saved


                      draft discarded


















                      bfink is a new contributor. Be nice, and check out our Code of Conduct.












                      bfink is a new contributor. Be nice, and check out our Code of Conduct.











                      bfink is a new contributor. Be nice, and check out our Code of Conduct.













                       


                      draft saved


                      draft discarded














                      StackExchange.ready(
                      function ()
                      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fdiy.stackexchange.com%2fquestions%2f148582%2fwhat-are-these-cloth-covered-wires%23new-answer', 'question_page');

                      );

                      Post as a guest













































































                      Comments

                      Popular posts from this blog

                      Long meetings (6-7 hours a day): Being “babysat” by supervisor

                      What does second last employer means? [closed]

                      One-line joke