I have measured S parameters of an 10 dB attenuator on hand--please see the attachment.



  • In my view, this attenuator is not performing as expected, e.g., |S12| / |S21| is not giving 10dB attenuation but rather it is giving ~20 dB attenuation (but varying over frequency).


  • the reflections, |S11|, are just too high. Also |S22| are just too high in low frequency, but high frequencies it is low.


But my question is, if you are asked to describe the characteristics of such an attenuator, then what else would you say?



Thank you



enter image description here










share|improve this question





















  • Are you comparing dB amplitude with dB power? In which case you will be a factor of two off.
    – Jack B
    2 hours ago










  • I have the measurement results of a "good" 10 dB attenuator, which shows the flat -10 dB attenuation level of |S21| / |S12|. So, I "think" the VNA converts in proper dB sense as 20*log10(abs(Sxx)), where abs(Sxx) is in amplitude sense.
    – learning
    2 hours ago










  • Is this a coaxial attenuator, did you use the correct torque wrench to make all connections (cable to VNA, VNA to DUT, VNA to standards during calibration)? If this is an on-chip attenuator or you're using microprobes to connect to it, are you sure you landed the probes correctly?
    – The Photon
    29 mins ago










  • It's a coaxial attenuator. Yes, I made sure all the connections are good.
    – learning
    16 mins ago














up vote
2
down vote

favorite












I have measured S parameters of an 10 dB attenuator on hand--please see the attachment.



  • In my view, this attenuator is not performing as expected, e.g., |S12| / |S21| is not giving 10dB attenuation but rather it is giving ~20 dB attenuation (but varying over frequency).


  • the reflections, |S11|, are just too high. Also |S22| are just too high in low frequency, but high frequencies it is low.


But my question is, if you are asked to describe the characteristics of such an attenuator, then what else would you say?



Thank you



enter image description here










share|improve this question





















  • Are you comparing dB amplitude with dB power? In which case you will be a factor of two off.
    – Jack B
    2 hours ago










  • I have the measurement results of a "good" 10 dB attenuator, which shows the flat -10 dB attenuation level of |S21| / |S12|. So, I "think" the VNA converts in proper dB sense as 20*log10(abs(Sxx)), where abs(Sxx) is in amplitude sense.
    – learning
    2 hours ago










  • Is this a coaxial attenuator, did you use the correct torque wrench to make all connections (cable to VNA, VNA to DUT, VNA to standards during calibration)? If this is an on-chip attenuator or you're using microprobes to connect to it, are you sure you landed the probes correctly?
    – The Photon
    29 mins ago










  • It's a coaxial attenuator. Yes, I made sure all the connections are good.
    – learning
    16 mins ago












up vote
2
down vote

favorite









up vote
2
down vote

favorite











I have measured S parameters of an 10 dB attenuator on hand--please see the attachment.



  • In my view, this attenuator is not performing as expected, e.g., |S12| / |S21| is not giving 10dB attenuation but rather it is giving ~20 dB attenuation (but varying over frequency).


  • the reflections, |S11|, are just too high. Also |S22| are just too high in low frequency, but high frequencies it is low.


But my question is, if you are asked to describe the characteristics of such an attenuator, then what else would you say?



Thank you



enter image description here










share|improve this question













I have measured S parameters of an 10 dB attenuator on hand--please see the attachment.



  • In my view, this attenuator is not performing as expected, e.g., |S12| / |S21| is not giving 10dB attenuation but rather it is giving ~20 dB attenuation (but varying over frequency).


  • the reflections, |S11|, are just too high. Also |S22| are just too high in low frequency, but high frequencies it is low.


But my question is, if you are asked to describe the characteristics of such an attenuator, then what else would you say?



Thank you



enter image description here







rf






share|improve this question













share|improve this question











share|improve this question




share|improve this question










asked 2 hours ago









learning

455




455











  • Are you comparing dB amplitude with dB power? In which case you will be a factor of two off.
    – Jack B
    2 hours ago










  • I have the measurement results of a "good" 10 dB attenuator, which shows the flat -10 dB attenuation level of |S21| / |S12|. So, I "think" the VNA converts in proper dB sense as 20*log10(abs(Sxx)), where abs(Sxx) is in amplitude sense.
    – learning
    2 hours ago










  • Is this a coaxial attenuator, did you use the correct torque wrench to make all connections (cable to VNA, VNA to DUT, VNA to standards during calibration)? If this is an on-chip attenuator or you're using microprobes to connect to it, are you sure you landed the probes correctly?
    – The Photon
    29 mins ago










  • It's a coaxial attenuator. Yes, I made sure all the connections are good.
    – learning
    16 mins ago
















  • Are you comparing dB amplitude with dB power? In which case you will be a factor of two off.
    – Jack B
    2 hours ago










  • I have the measurement results of a "good" 10 dB attenuator, which shows the flat -10 dB attenuation level of |S21| / |S12|. So, I "think" the VNA converts in proper dB sense as 20*log10(abs(Sxx)), where abs(Sxx) is in amplitude sense.
    – learning
    2 hours ago










  • Is this a coaxial attenuator, did you use the correct torque wrench to make all connections (cable to VNA, VNA to DUT, VNA to standards during calibration)? If this is an on-chip attenuator or you're using microprobes to connect to it, are you sure you landed the probes correctly?
    – The Photon
    29 mins ago










  • It's a coaxial attenuator. Yes, I made sure all the connections are good.
    – learning
    16 mins ago















Are you comparing dB amplitude with dB power? In which case you will be a factor of two off.
– Jack B
2 hours ago




Are you comparing dB amplitude with dB power? In which case you will be a factor of two off.
– Jack B
2 hours ago












I have the measurement results of a "good" 10 dB attenuator, which shows the flat -10 dB attenuation level of |S21| / |S12|. So, I "think" the VNA converts in proper dB sense as 20*log10(abs(Sxx)), where abs(Sxx) is in amplitude sense.
– learning
2 hours ago




I have the measurement results of a "good" 10 dB attenuator, which shows the flat -10 dB attenuation level of |S21| / |S12|. So, I "think" the VNA converts in proper dB sense as 20*log10(abs(Sxx)), where abs(Sxx) is in amplitude sense.
– learning
2 hours ago












Is this a coaxial attenuator, did you use the correct torque wrench to make all connections (cable to VNA, VNA to DUT, VNA to standards during calibration)? If this is an on-chip attenuator or you're using microprobes to connect to it, are you sure you landed the probes correctly?
– The Photon
29 mins ago




Is this a coaxial attenuator, did you use the correct torque wrench to make all connections (cable to VNA, VNA to DUT, VNA to standards during calibration)? If this is an on-chip attenuator or you're using microprobes to connect to it, are you sure you landed the probes correctly?
– The Photon
29 mins ago












It's a coaxial attenuator. Yes, I made sure all the connections are good.
– learning
16 mins ago




It's a coaxial attenuator. Yes, I made sure all the connections are good.
– learning
16 mins ago










1 Answer
1






active

oldest

votes

















up vote
6
down vote



accepted










It is very likely that port 1 of the attenuator has a bad connection, possibly due to a broken connector. Somewhere, the RF is passing through a capacitive coupling instead of a direct connection.



Evidence:



1) Attenuation is higher than expected - 20dB instead of 10dB



2) The match is asymmetric - port 2 is well matched, port 1 is basically reading an open circuit.



You can verify this with a multimeter. A healthy attenuator will read some resistance (say, <100 ohm) between the input and output, and similar between each input and ground. Your attenuator, I believe, will read an open circuit between input and output.






share|improve this answer




















    Your Answer




    StackExchange.ifUsing("editor", function ()
    return StackExchange.using("mathjaxEditing", function ()
    StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix)
    StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
    );
    );
    , "mathjax-editing");

    StackExchange.ifUsing("editor", function ()
    return StackExchange.using("schematics", function ()
    StackExchange.schematics.init();
    );
    , "cicuitlab");

    StackExchange.ready(function()
    var channelOptions =
    tags: "".split(" "),
    id: "135"
    ;
    initTagRenderer("".split(" "), "".split(" "), channelOptions);

    StackExchange.using("externalEditor", function()
    // Have to fire editor after snippets, if snippets enabled
    if (StackExchange.settings.snippets.snippetsEnabled)
    StackExchange.using("snippets", function()
    createEditor();
    );

    else
    createEditor();

    );

    function createEditor()
    StackExchange.prepareEditor(
    heartbeatType: 'answer',
    convertImagesToLinks: false,
    noModals: false,
    showLowRepImageUploadWarning: true,
    reputationToPostImages: null,
    bindNavPrevention: true,
    postfix: "",
    onDemand: true,
    discardSelector: ".discard-answer"
    ,immediatelyShowMarkdownHelp:true
    );



    );













     

    draft saved


    draft discarded


















    StackExchange.ready(
    function ()
    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f403554%2fthe-s-parameters-of-an-attenuator-but-what-is-actually-wrong-with-it%23new-answer', 'question_page');

    );

    Post as a guest






























    1 Answer
    1






    active

    oldest

    votes








    1 Answer
    1






    active

    oldest

    votes









    active

    oldest

    votes






    active

    oldest

    votes








    up vote
    6
    down vote



    accepted










    It is very likely that port 1 of the attenuator has a bad connection, possibly due to a broken connector. Somewhere, the RF is passing through a capacitive coupling instead of a direct connection.



    Evidence:



    1) Attenuation is higher than expected - 20dB instead of 10dB



    2) The match is asymmetric - port 2 is well matched, port 1 is basically reading an open circuit.



    You can verify this with a multimeter. A healthy attenuator will read some resistance (say, <100 ohm) between the input and output, and similar between each input and ground. Your attenuator, I believe, will read an open circuit between input and output.






    share|improve this answer
























      up vote
      6
      down vote



      accepted










      It is very likely that port 1 of the attenuator has a bad connection, possibly due to a broken connector. Somewhere, the RF is passing through a capacitive coupling instead of a direct connection.



      Evidence:



      1) Attenuation is higher than expected - 20dB instead of 10dB



      2) The match is asymmetric - port 2 is well matched, port 1 is basically reading an open circuit.



      You can verify this with a multimeter. A healthy attenuator will read some resistance (say, <100 ohm) between the input and output, and similar between each input and ground. Your attenuator, I believe, will read an open circuit between input and output.






      share|improve this answer






















        up vote
        6
        down vote



        accepted







        up vote
        6
        down vote



        accepted






        It is very likely that port 1 of the attenuator has a bad connection, possibly due to a broken connector. Somewhere, the RF is passing through a capacitive coupling instead of a direct connection.



        Evidence:



        1) Attenuation is higher than expected - 20dB instead of 10dB



        2) The match is asymmetric - port 2 is well matched, port 1 is basically reading an open circuit.



        You can verify this with a multimeter. A healthy attenuator will read some resistance (say, <100 ohm) between the input and output, and similar between each input and ground. Your attenuator, I believe, will read an open circuit between input and output.






        share|improve this answer












        It is very likely that port 1 of the attenuator has a bad connection, possibly due to a broken connector. Somewhere, the RF is passing through a capacitive coupling instead of a direct connection.



        Evidence:



        1) Attenuation is higher than expected - 20dB instead of 10dB



        2) The match is asymmetric - port 2 is well matched, port 1 is basically reading an open circuit.



        You can verify this with a multimeter. A healthy attenuator will read some resistance (say, <100 ohm) between the input and output, and similar between each input and ground. Your attenuator, I believe, will read an open circuit between input and output.







        share|improve this answer












        share|improve this answer



        share|improve this answer










        answered 1 hour ago









        Selvek

        1,759111




        1,759111



























             

            draft saved


            draft discarded















































             


            draft saved


            draft discarded














            StackExchange.ready(
            function ()
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f403554%2fthe-s-parameters-of-an-attenuator-but-what-is-actually-wrong-with-it%23new-answer', 'question_page');

            );

            Post as a guest













































































            Comments

            Popular posts from this blog

            What does second last employer means? [closed]

            Installing NextGIS Connect into QGIS 3?

            One-line joke